Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - DBL POLE
Sort By:
1 2 3 4
BREAKER CIRCUIT 2POLE 1IN 40A Cutler-Hammer BR215 Circuit Breaker, Mini, Type BR, 15 A, 2 -Pole, 120/240 V, Plug Mounting CIRCUIT BRKR TBA 2P2SPC 20/20A
Suggested Retail: $19.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
BREAKER CIRCUIT 2POLE 1IN 40A Eaton BR215 Type BR Miniature Circuit Breaker CIRCUIT BRKR TBA 2P2SPC 20/20A
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2" per pole. UL Listed, HACR rated. 15 to 25 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 30 to 50 amp 8 - 4 Cu or 8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
CIRCUIT BRKR TBA 2P2SPC 30/30A BREAKER BR 2P 50 AMP 10KA GE THQL2120 Feeder Circuit Breaker, Type THQL, 20 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
CIRCUIT BRKR TBA 2P2SPC 30/30A BREAKER BR 2P 50 AMP 10KA     GE THQL2120 Type THQL Q-Line Standard Circuit Breaker
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).
GE THQL2130 Feeder Circuit Breaker, Type THQL, 30 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug GE THQL2140 Feeder Circuit Breaker, Type THQL, 40 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug GE THQL2150 Feeder Circuit Breaker, Type THQL, 50 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
GE THQL2130 Type THQL Q-Line Standard Circuit Breaker GE THQL2140 Type THQL Q-Line Standard Circuit Breaker GE THQL2150 Type THQL Q-Line Standard Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).
GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug CIRCUIT BREAKR THQP 2P 1IN 50A BREAKER CIRCUIT 2POLE 1IN 30A
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
GE THQL2160 Type THQL Q-Line Standard Circuit Breaker CIRCUIT BREAKR THQP 2P 1IN 50A BREAKER CIRCUIT 2POLE 1IN 30A
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total). Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2" per pole. UL Listed, HACR rated. 15 to 25 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 30 to 50 amp 8 - 4 Cu or 8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2" per pole. UL Listed, HACR rated. 15 to 25 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 30 to 50 amp 8 - 4 Cu or 8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
GE THQP220 Feeder Circuit Breaker, Type THQP, 20 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug Cutler-Hammer BR225 Circuit Breaker, Mini, Type BR, 25 A, 2 -Pole, 120/240 V, Common Trip, Plug Mounting CIRCUIT BREAKER HOM 2P 1IN 15A
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
GE THQP220 Type THQP Q-Line Miniature Circuit Breaker Eaton BR225 Type BR Miniature Circuit Breaker CIRCUIT BREAKER HOM 2P 1IN 15A
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 cu or 12 to 8 al AWG wire, 30 to 50 A 8 to 4 cu or 8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
CIRCUIT BREAKER HOM 2P 1IN 30A CIRCUIT BREAKER HOM 2P 1IN 40A CIRCUIT BREAKER HOM 2P 1IN 50A
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
CIRCUIT BREAKER HOM 2P 1IN 30A CIRCUIT BREAKER HOM 2P 1IN 40A CIRCUIT BREAKER HOM 2P 1IN 50A
Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
CIRCUIT BREAKER HOM 2P 1IN 60A CIRCUIT BREAKER HOM 2P 1IN 20A CIRCUIT BRKR TBA 2P2SPC 40/40A
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
CIRCUIT BREAKER HOM 2P 1IN 60A CIRCUIT BREAKER HOM 2P 1IN 20A CIRCUIT BRKR TBA 2P2SPC 40/40A
Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
Cutler-Hammer BR260 Circuit Breaker, Type BR, 60 A, 2-Pole, 120/240 V, Plug Square D Homeline HOM250C Circuit Breaker, Mini, 50 A, 2 -Pole, 120/240 V, Plug Mounting, Black Square D Homeline HOM260C Circuit Breaker, Mini, 60 A, 2 -Pole, 120/240 V, Plug Mounting, Black
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Suggested Retail: $21.99
more info
Eaton BR260 Type BR Miniature Circuit Breaker HomeLine HOM250C Miniature Standard Circuit Breaker HomeLine HOM260C Miniature Standard Circuit Breaker
Cutler-Hammer Circuit Breaker, Type BR, 120/240 V, 60 A, Operating Frequency: 50/60 Hz, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 42 kA, Wire Size: 8 to 1/0 AWG, Plug Mounting, Dimensions: 2.93 in L x 1.96 in W x 2.92 in H, Operating Temperature: 60 to 75 deg C Engineered for value, Homeline? circuit breakers are designed for fast installation, reliability and great circuit protection. With industry leading innovations and exclusive features, Square D Homeline circuit breakers are the smart, safe, reliable choice. Engineered for value, Homeline? circuit breakers are designed for fast installation, reliability and great circuit protection. With industry leading innovations and exclusive features, Square D Homeline circuit breakers are the smart, safe, reliable choice.
Siemens Q220 Circuit Breaker, Mini, 20 A, 2 -Pole, 120/240 V, Fixed Trip, Plug Mounting Siemens Q230 Circuit Breaker, Mini, 30 A, 2 -Pole, 120/240 V, Fixed Trip, Plug Mounting Siemens Q240 Circuit Breaker, Mini, 40 A, 2 -Pole, 120/240 V, Fixed Trip, Plug Mounting
Suggested Retail: $22.99
more info
Suggested Retail: $22.99
more info
Suggested Retail: $22.99
more info
MES Q220 Standard Miniature Circuit Breaker MES Q230 Standard Miniature Circuit Breaker MES Q240 Standard Miniature Circuit Breaker
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total).
Siemens Q250 Circuit Breaker, Mini, 50 A, 2 -Pole, 120/240 V, Fixed Trip, Plug Mounting Siemens Q260 Circuit Breaker, Mini, 60 A, 2 -Pole, 120/240 V, Fixed Trip, Plug Mounting Siemens Q215 Circuit Breaker, 15 A, 2 -Pole, 120/240 V, Plug Mounting
Suggested Retail: $22.99
more info
Suggested Retail: $22.99
more info
Suggested Retail: $22.99
more info
MES Q250 Standard Miniature Circuit Breaker MES Q260 Standard Miniature Circuit Breaker BREAKER CIRC 2-POLE 240V 15A
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Siemens Circuit Breaker, 120/240 V, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, QP Frame, 2 in Frame, Magnetic, Thermal Actuator, 14 to 6 AWG Wire, Lug Terminal, Plug Mounting, Dimensions: 3 in L x 3 in W x 2 in H, 40 deg C Operating
   
 
1 2 3 4