Cutler-Hammer BRFPP Filler Plate, 3 in L, 1 in W, Plastic, For: 1 in Circuit Breakers, 400 a and 600 a Load Centers
|
|
GE THFILLERP Filler Plate Kit, 6-7/8 in L, 2-7/8 in W
|
|
GE TGL1P Ground Bar Kit, 1/2 in L, 7-Terminal
|
|
|
|
|
|
|
|
|
Plastic (snap-in) for type BR 1 in space. May also be used with 400 and 600 A load centers.
|
GE Filler Plate Kit, 6-7/8 in Length, 2-7/8 in Width, 3/4 in Height
|
For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 to 8 AWG copper or 12 to 8 AWG aluminum terminals and 3 large holes for 14 to 4 AWG copper or 12 to 4 AWG aluminum terminals. UL listed and ANSI certified. 6-7/8 in H x 2-7/8 in W x 1/2 in depth, 0.105 lb.
|
|
|
Square D Homeline QOFPCP Filler Plate, 3 in L, 1-1/2 in W, For: QO Load Centers
|
|
GE TLK20CP Neutral/Ground Lug Kit, 6 to 2/0 AWG Wire
|
|
Square D Homeline HOMFPCP Filler Plate, 3 in L, 1-1/2 in W, For: Homeline Load Centers
|
|
|
|
|
|
|
|
|
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified.
|
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL listed. 2-7/8 in H x 3/4 in W x 6-7/8 in D, 0.07 lb.
|
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline? load centers. UL listed and ANSI Certified.
|
|
|
Cutler-Hammer GBKP10P Ground Bar Kit, 4.7 in L, 10 -Terminal
|
|
Square D PK3GTA-1CP Ground Bar Kit, 3 -Terminal, Aluminum
|
|
Siemens ECQF3P Filler Plate, 1 in W, Plastic, Black
|
|
|
|
|
|
|
|
|
Cutler-Hammer Ground Bar Kit, 10 Terminals, 4.7 in Length, 2.3 in Width, 1/2 in Height
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Siemens Filler Plate, Plastic, Black, 1 in Width, 3 in Height
|
|
|
Square D PK4GTACP Ground Bar Kit, 4 -Terminal, Aluminum
|
|
Eaton GBKP14P Ground Bar Kit, 5.69 in L, 14-Terminal, 14 to 4 AWG Wire
|
|
Square D PK7GTACP Ground Bar Kit, 7 -Terminal, Aluminum
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Eaton Ground Bar Kit, Number of Terminals: 14, Wire Size: 14 to 4 AWG, 5.69 in L
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
GE TGK24CP Ground Bar Kit, 1/2 in L, 24-Terminal, 10 to 12 AWG Aluminum, 4 to 14 AWG Copper Wire
|
|
Schneider Electric LK70ANCP Lug Kit
|
|
Siemens ECGB10 Ground Bar Kit, 10 -Terminal, 14 to 4 AWG Wire, Aluminum/Copper
|
|
|
|
|
|
|
|
|
Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL listed and ANSI certified. 11 in H x 3-1/2 in W x 1/2 in D, 0.304 lb.
|
QO? Circuit Breaker Load Centers, LK70ANCP, from Square D? are Underwriters Laboratories (UL) Listed and CSA rated panelboards. They are designed to meet residential, commercial and industrial requirements to protect electrical systems, equipment and people.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
|
|
Square D PK9GTACP Ground Bar Kit, 9 -Terminal, Aluminum
|
|
Cutler-Hammer GBKP21P Ground Bar Kit, 21 -Terminal
|
|
Square D PK12GTACP Ground Bar Kit, 12 -Terminal, Aluminum
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Cutler-Hammer Ground Bar Kit, 21 Terminals
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
Square D PK15GTACP Ground Bar Kit, 15 -Terminal, Aluminum
|
|
Square D PK18GTACP Ground Bar Kit, 18 -Terminal, Aluminum
|
|
Siemens EC2GB152 Ground Bar Kit, 12-1/4 in L, 15 -Terminal, 14 to 4 AWG Wire, Aluminum/Copper
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
|
|
Square D PK23GTACP Ground Bar Kit, 23 -Terminal, Aluminum
|
|
Siemens EC3GB302 Ground Bar Kit, 15-3/4 in L, 30 -Terminal, 14 to 4 AWG Wire, Aluminum/Copper
|
|
LOAD CENTER COVER SCREWS PACK6 - Case of 5
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws.
|
|
|
Cutler-Hammer BRL200 Main Lug Kit, 200 A, 120/240 VAC, 1 to 300 kcmil Wire
|
|
Square D Qo Lk100ancp Load Center Neutral Kit - Case of 10
|
|
|
|
|
Suggested Retail: $119.99
|
|
|
|
|
|
Cutler-Hammer Main Lug Kit, 120/240 VAC, 200 A, 1 to 300 kcmil Wire
|
Square D QO Load Center Neutral Kit, Specifications: 6 to 250 AWG Copper or Aluminum Wire, 23 to 104 deg F Temperature
|
|